SP-1000 (1000W power supply with PFC))
|
Features & Specif ications
Universal AC input/Full range
Built-in active PFC function,PF>0.93@230VAC
Protection:Short circuit / over load / over voltage
Approval:CE
100% full load burn-in test
LED indicator for power on.
High reliability,low cost
2 years warranty
INDEX TYPE
|
SP-1000-24
|
SP-1000-36
|
SP-1000-48
|
DC VOLTAGE
|
24V
|
36V
|
48V
|
RATED CURRENT
|
41.6A
|
27.8A
|
20.8A
|
RIPPLE&NOISE (MAX.)
|
120mVp-p
|
120mVp-p
|
150mVp-p
|
LINE REGULATION
|
±0.5%
|
±0.5%
|
±0.5%
|
LOAD REGULATION
|
±0.5%
|
±0.5%
|
±0.5%
|
RATED POWER
|
1000W
|
1000W
|
1000W
|
EFFICIENCY
|
84%
|
86%
|
87%
|
VOLTAGE ADJ.RANGE
|
±10%
|
VOLTAGE RANGE
|
88~264VAC 47-63Hz
|
PFC
|
PF>0.98%@115VAC,PF>0.95@230VAC
|
INRUSH CURRENT (MAX.)
|
45A/230V
|
OVERLOAD PROTECTION
|
105-135% TYPE:Current limitation auto recovery
|
OVERVOLTAGE PROTECTION
|
115-140% rated output voltage
|
TEMP.COEFFICIENT
|
±0.03%/℃(0~50℃)
|
SETUP.RISE,
|
300ms,50ms,
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVACI/P-FG:1.5KVACI/P-FG:0.5KVAC
|
ISOLATED RESISTOR
|
I/P-O/P,I/P-FG,I/P-FG:500VDC/100MΩ
|
WORKING TEMP.HUMIDITY
|
-10℃~+50℃,20%~90RH
|
STORAGE TEMP.HUMIDITY
|
-20℃~+85℃,10%~95%RH
|
DIMENSION
|
295×127×41mm
|
WEIGHT
|
2Kgs
|
COOLING METHOD
|
FAN
|
SAFETY STANDARDS
|
TO MEET CE,TUV EN60950
|
EMC
|
CISPR22(EN 55022),IEC1000-4,2,3,4,5,6,8,11 IEC1000
|
|
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation :min&max voltage of the rated load.
5.load regulation: load from 0 to 100%.