Time:2010-1-25 Views:1945

S-300  (Single Output)

 

         Features & Specifications

         AC input by switch

         Protection:Short circuit / over load / over voltage
         Approval:CE
         100% full load burn-in test
         High reliability,low cost
         2 years warranty

 

INDEX TYPE S-300-5 S-300-7.5 S-300-12 S-300-13.5 S-300-15 S-300-24 S-300-48
DC VOLTAGE 5V 7.5V 12V 13.5V 15V 24V 48V
VOLTAGE TOLERANCE ±2% ±2% ±1% ±1% ±1% ±1% ±1%
RATED CURRENT 60A 42.6A 25A 22.2A 20A 12.5A 6.25A
CURRENT RANGE 0-60A 0-42.6A 0-25A 0-22.5A 0-20A 0-12.5A 0-6.25A
RIPPLE&NOISE (MAX.) 150mVp-p 150mVp-p 180mVp-p 180mVp-p 180mVp-p 180mVp-p 240mVp-p
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
RATED POWER 300W 300W 300W 300W 300W 300W 300W
EFFICIENCY 77% 80% 82% 83% 85% 86% 87%
VOLTAGE ADJ.RANGE 4.5-5.7V 6-9V 10-13.2V 12-15V 13.5-18V 20-26.4V 41-56V
VOLTAGE RANGE 88~132VAC/176~264VAC SELECTED BY SWTCH 4
AC CURRENT 6A/115V 3.5A/230V
INRUSH CURRENT (MAX.) 20A/115V 40A/230V
LEAKAGE CURRENT <3.5mA/240VAC
OVERLOAD PROTECTION 105%~135% SHUT DOWN RESET
OVERVOLTAGE PROTECTION 5.75-6.75V 9.4-10.9V 13.8-16.2V 15.5-18.2V 18-21V 27.6-32.4V 57.6-67.2V
OVER TEMP. PROTECTION RTH1>=65℃ FAN ON<=55℃ FAN OFF>=70℃ SHUT DOWN
TEMP.COEFFICIENT ±0.03%℃(0~50℃)
SETUP.RISE,HOLD TIME 2s,20ms,20ms
VIBRATION 10~500Hz,2G 10min/1cycle,60min,each axes
WITHSTAND VOLTAGE I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
ISOLATED RESISTOR I/P-O/P,I/P-FG,O/P-FG:500VDC/100MΩ
WORKING TEMP.HUMIDITY -10℃~+60℃,20%~90%RH
STORAGE TEMP.HUMIDITY -20℃~+85℃,10%~95%%RH
DIMENSION 215*115*50mm
WEIGHT 1.15Kgs
SAFETY STANDARDS TO MEET UL1950 TUVEN60950
EMC EN55022 CLASSB EN61000-4,2,3,4 EN60555-2,3

 

Note:
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation :min&max voltage of the rated load.
5.load regulation: load from 0 to 100%. 

 
 